Temperature Controller
| Offer Type: |
|
|---|---|
| Offer Post Time: | 2009-11-07 |
| Expiration Date: | 2010-04-18 |
| Details: |
Temperature Controller
(1). (2). (3). (4). (5). (6). (7) (1)- Intelligent dual digital display instrument regulating code (2)- Instrument Dimensions (W * H) Space: 160*80mm A: 96*96mm D: 72*72mm E: 48*96mm F: 96*48mm G: 48*48mm S: 80*160mm 3 - Designed Serial Number (4) - output mode: 0: Output contacts of the digital on-off adjustment (contact capacity 220V, 3A resistive) 1: 1 ~ 5V DC output voltage signal for the PID regulator 2: Output contacts of the two-off or time proportional PID regulator adjustment 3: Output DC 0 ~ 5V or 1 ~ 5V or 0 ~ 10V voltage signal for the PID regulator 4: DC 4 ~ 20mA output current signal for the PID regulator 5: Solid state relay output driver (SSR) of the two PID regulator 6: Output single-phase thyristor phase-shifted signal to trigger the PID regulator (SCR regulator) 7: The output of single-phase zero-crossing triac trigger signal PID regulator (SCR Power Regulator) 8: Three-phase SCR trigger signal output of the PID regulator with additional devices (three-phase reactive power transfer) 9: Output DC 0 ~ 10mA current signal for the PID regulator (5) - alarm mode 0: No alarm 1: The absolute upper limit alarm contact output function (contact capacity 220V, 3A resistive) 2: With a minimum absolute alarm contact output function 3: The lower and upper limit contact output alarm function 4: The upper limit deviation alarm 5: Minimum deviation alarm 6: On, the lower limit deviation alarm 7: On the upper limit absolute alarm 8: On the upper limit deviation value alarm 9: User requested alarm other means (language note when ordering) (6) - input signal 1: Thermocouple (K, E, S, B, J, T, R, N, etc. ) 2: Thermal Resistance (PT100, Cu50, Cu100, BA1, BA2, G, etc. ) 3: Standard voltage (0 ~ 5V, 1 ~ 5V, 0 ~ 10V, etc. ) 4: Standard resistance (0 ~ 400¦¸ and so on, such as pressure resistance FarEasTone YTZ-150) 5: 0 ~ 10mA current standards 6: Standard current 4 ~ 20mA 9: The special requirements of users of other signal input (7) - Instrumentation Additional features V: DC 24V with feed output (transmitter power can be used) T: Timing belt P: Thirty paragraph with control (heating curve) B: Transmission output current and voltage signals (corresponding to the input can be isolated) Q: Other special features users demand |
Most Popular
-

Strontium Ferrite Magnet Strontium ferrite magnet, ferrite arc magnet for ... -

Volumeteric Meters Series (LXH-8/F LXH-8) WORKING PRINCIPLES: A certain amount of water ... -

Thermometer (JWC-1) Temperature range: -50 degree~ 50 degree. ...
-

Steel Switch Box We can supply Octagonal metal box, 2"X2" metal ... -

Laser Wire / Cable Stripper Product Description Production Introduction ... -

Socket (A-2.107) Socket, Binding Post, Crocodile Clip 4mm PCB ...
-

Three Phase Active Kilo Watt-Hour Meter (DDSY523) DDSY523 Three Phase Active Kilo Watt-Hour ... -

Fan-Out Cord Our Fan-Out Cord Assemblies are available in 4 ... -

WVTR Tester for Flexible Electronics Materials Labthink Stella Li report: Labthink newly ...
-

Electric Snow Blower (PRSB5001) 1. 650w Powerful Magnetic Motor 2. Snow Exit In ... -

3 in 1 Digital Tyre Gauge (DTG31) 3 in 1 Digital Tyre Gauge Spesifications(Tyre ... -

Colorful Handheld DSO Established in 1995, Lilliput Electronics Co., ...
-

Panel Meter Our panel meter contains Ammeter, voltmeter, ... -

Aluminum Panel Aluminum Extrusion Faceplate with Fully Machined ... -

Wireless Controller with SensorSix-axis Function for PS3 Wireless Controller with SensorSix-axis Function ...
Related Searches |
Inquiry Basket (





